01
Transformer Pengagihan Aloi Amorfus S(B)H15M
Ciri-ciri Produk
◇ GB/T10228-1997, GB6450-1986, JB/T10088-2004, GB4208-1993
◇ Voltan tinggi yang dinilai: 10 (11, 10.5, 6.6, 6.3, 6)kV
◇ Voltan tinggi yang dinilai: 10 (11, 10.5, 6.6, 6.3, 6)kV
◇ Tekanan rendah dinilai: 0.4kV
◇ Kumpulan sambungan: Dynl1orYY
◇ Julat penorehan voltan tinggi: ±5% atau ±2×2.5%
◇ Tahap penebat: LI75AC35/LI OAG5
◇ Tahap penebat: LI75AC35/LI OAG5
◇ Frekuensi: 50Hz
Maksud model

Parameter prestasi produk
| Kapasiti dinilai | Gabungan voltan (kV) | Label kumpulan pautan | Kehilangan tanpa beban | Kehilangan beban | Arus tanpa beban | Voltan impedans | ||
| tekanan tinggi | Julat penguraian tekanan tinggi (%) | Tekanan rendah | ||||||
| 30 | 6 6.3 6.6 10 10.5 11 | ±2×2.5 ±5 | 0.4 | Dyn11 Yyn0 | 33 | 630/600 | 1.5 | 4 |
| 50 | 43 | 910/870 | 1.2 | |||||
| 63 | 50 | 1090/1040 | 1.1 | |||||
| 80 | 60 | 1310/1250 | 1 | |||||
| 100 | 75 | 1580/1500 | 0.9 | |||||
| 125 | 85 | 1890/1800 | 0.8 | |||||
| 160 | 100 | 2310/2200 | 0.6 | |||||
| 200 | 120 | 2730/2600 | 0.6 | |||||
| 250 | 140 | 3200/3050 | 0.6 | |||||
| 315 | 170 | 3830/3850 | 0.5 | |||||
| 400 | 200 | 4520/4300 | 0.5 | |||||
| 500 | 240 | 5410/5150 | 0.5 | |||||
| 630 | 320 | 6200 | 0.3 | 4.5 | ||||
| 800 | 380 | 7500 | 0.3 | |||||
| 1000 | 450 | 10300 | 0.3 | |||||
| 1250 | 530 | 12000 | 0.2 | |||||
| 1600 | 630 | 14500 | 0.2 | |||||
| 2000 | 750 | 18300 | 0.2 | 5 | ||||
| 2500 | 21200 | 0.2 | 5 | |||||
Nota: Disebabkan oleh kemas kini produk yang berterusan, parameter dalam jadual mungkin berubah. Sila rujuk parameter yang disediakan semasa membuat pesanan.
Nota 1: Apabila terasnya ialah lajur tiga fasa, kumpulan sambungan Yyn0 juga boleh digunakan mengikut keperluan.
Nota 2: Bagi transformer tiga fasa dengan kapasiti undian 500kVA dan ke bawah, nilai kehilangan beban di atas garis miring dalam jadual boleh digunakan untuk kumpulan sambungan Dyn11, dan nilai kehilangan beban di bawah garis miring boleh digunakan untuk kumpulan sambungan Yyn0.
Nota 3: Nilai kerugian lain boleh dipilih jika dikehendaki oleh pengguna.
Nota 4: Transformer tiga fasa dengan julat penorehan voltan tinggi yang lain boleh disediakan mengikut keperluan pengguna.
Parameter prestasi produk (sambungan)
| Kapasiti dinilai | Gabungan voltan (kV) | Label kumpulan pautan | Kehilangan tanpa beban | Kehilangan beban | Arus tanpa beban | Voltan impedans | ||
| tekanan tinggi | Julat penguraian tekanan tinggi (%) | Tekanan rendah | ||||||
| 30 | 20 | ±2×2.5 ±5 | 0.4 | Dyn11 | 40 | 690/660 | 1.5 | 5.5 |
| 50 | 55 | 1010/960 | 1.2 | |||||
| 63 | 65 | 1200/1150 | 1.1 | |||||
| 80 | 75 | 1440/1370 | 1 | |||||
| 100 | 90 | 1720/1650 | 0.9 | |||||
| 125 | 100 | 2080/1980 | 0.8 | |||||
| 160 | 120 | 2540/2420 | 0.6 | |||||
| 200 | 145 | 3000/2860 | 0.6 | |||||
| 250 | 165 | 3520/3350 | 0.6 | |||||
| 315 | 200 | 4210/4010 | 0.5 | |||||
| 400 | 240 | 4970/4730 | 0.5 | |||||
| 500 | 290 | 5940/5560 | 0.5 | |||||
| 630 | 370 | 6820/8250 | 0.3 | 6 | ||||
| 800 | 450 | 11330 | 0.3 | |||||
| 1000 | 530 | 13200 | 0.3 | |||||
| 1250 | 620 | 15950 | 0.2 | |||||
| 1600 | 750 | 19140 | 0.2 | |||||
| 2000 | 900 | 22220 | 0.2 | |||||
| 2500 | 1080 | 21200 | 0.2 | |||||
Nota 1: Apabila terasnya tiga fasa dan tiga lajur, ia juga boleh digunakan mengikut keperluan. Kumpulan Sambungan Yyn0.
Nota 2: Untuk kapasiti undian 500kv Bagi transformer di bawah 1000A, nilai kehilangan beban di atas garis miring dalam jadual terpakai pada Dyn11. Nilai kehilangan beban di bawah garis miring terpakai pada kumpulan yang disambungkan. Kumpulan Sambungan Yyn0.
Nota 3: Nilai kerugian lain boleh dipilih jika dikehendaki oleh pengguna.
Nota 4: Transformer dengan julat penorehan voltan tinggi yang lain boleh disediakan mengikut keperluan pengguna.
Nota 5: Parameter prestasi dalam jadual juga boleh digunakan untuk Transformer 20 (10)kV voltan tinggi
Nota 6: Disebabkan oleh kemas kini produk yang berterusan, parameter dalam jadual mungkin berubah. Sila rujuk parameter yang disediakan semasa membuat pesanan.
Produk memenuhi piawaian
◇ GB 1094. 1-1996 Transformer kuasa Bahagian 1 Umum
◇ GB1094.2-1996 Kenaikan suhu bahagian kedua transformer kuasa
◇ GB1094.3-2003 Transformer kuasa - Bahagian 3 Tahap penebat, ujian penebat dan jurang udara penebat luaran
◇ GB1094.5-2008 Keupayaan litar pintas bahagian 5 transformer kuasa
◇ GB/T25446-2010 Parameter teknikal dan keperluan transformer pengedaran teras aloi amorfus terendam minyak
◇ GB311. 1-1997 Penyelarasan penebat peralatan penghantaran dan transformasi kuasa voltan tinggi
◇ IEG 60076 Pengubah Kuasa
◇ ANSI/C57.12.00 Keperluan teknikal am untuk transformer pengagihan, pengawal kuasa dan voltan terendam minyak